Functions:
• the ability to handle max. 50 thermoelectric actuators, zones can be created using 8 dedicated wired regulators or wireless system regulators or temperature sensors, or wired temperature sensors C-7p:
– 3 zones with 3 outputs each (if there are more actuators, the maximum output load is 0,3A)
– 5 zones with 2 outputs each (if there are more actuators, the maximum output load is 0,3A)
• one 230V output for a pump
• voltage-free relay (to control an additional heating device)
• possibility of controlling wireless actuators STT-869/G-X (the maximum of 6 per zone)
• in each zone, it is possible to install up to 6 wireless EU-C-2n window opening sensors
• possibility of connecting 6 executive modules EU-MW-1 or EU-MW-1/230
• possibility of connecting EU-i-1 or EU-i-1m valve module
• up to 4 EU-ML-12 slaves can be connected
• the EU-M-12 control panel can be connected
• possibility to control the installation via the Internet, eModul application - EU-WiFi L module included
• heating/cooling function
• software update via USB
• OpenTherm communication
Power suply | 230V 50Hz |
Pump output load | 0,5 A |
Outputs 1 - 8 load | 0,3 A |
Voltage-free relay | • / 0,5 A |
Communications | Wired - TECH SBUS Wireless WTP - 868 MHz |
Dimensions [mm] | 343 x 118 x 52 |